UBT Catheter
| | Uterine Balloon Tamponade (UBT) Catheter consists of a water-filled balloon inserted into the uterine cavity to apply pressure to the walls of the mothers’ uterus to stop excessive bleeding after delivery thus providing a simple, rapid, affordable and effective way of managing PPH (postpartum haemorrhage). |
| | UBT catheters have been widely used for bleeding following caesarean sections, in cases of placenta praevia and accrete, post-abortion care, and induction of labor. |
| | Check valve simplify and expedite the inflation process. |
| | 2-Way UBT catheter equipped with a lumen that allows healthcare providers to monitor intrauterine blood drainage and assess the effectiveness of the tamponade. |


| | Uterine Balloon Tamponade (UBT) Catheter consists of a water-filled balloon inserted into the uterine cavity to apply pressure to the walls of the mothers’ uterus to stop excessive bleeding after delivery thus providing a simple, rapid, affordable and effective way of managing PPH (postpartum haemorrhage). |
| | UBT catheters have been widely used for bleeding following caesarean sections, in cases of placenta praevia and accrete, post-abortion care, and induction of labor. |
| | Check valve simplify and expedite the inflation process. |
| | 2-Way UBT catheter equipped with a lumen that allows healthcare providers to monitor intrauterine blood drainage and assess the effectiveness of the tamponade. |

Specifications
Type | 1-way | |
Length(mm) | 320+/-10 | |
Shaft Gauge (fr) | 20 | |
Balloon Capacity (ml) | 500 | |
Valve Choice | Soft Valve |
Specifications
Type | 2-way | |
Length(mm) | 320+/-10 | 520+/-10 |
Shaft Gauge (fr) | 20 | 24 |
Balloon Capacity (ml) | 500 | 1000 |
Valve Choice | Soft Valve |
Quality Control
Manufactured to EN1616 and in ISO 9001 / ISO 13485 registered environment |
Every individual catheter is subjected to 100% inspection of the following :- |
Surface smoothness |
Gauge (Dimensional Specification) |
Balloon Symmetricity |
Rounded Drainage Hole (2-Way) |
Funnel Strength at Bifurcation (2-Way) |
Type | Length(mm) | Shaft Gauge (fr) | Balloon Capacity (ml) | Valve Choice |
1-way | 320+/-10 | 20 | 500 | Soft Valve |
2-way | 320+/-10 | 20 | 500 | |
520+/-10 | 24 | 1000 |
Manufactured to EN1616 and in ISO 9001 / ISO 13485 registered environment | ||
Every individual catheter is subjected to 100% inspection of the following :- | ||
Surface smoothness | Gauge (Dimensional Specification) | Balloon Symmetricity |
Rounded Drainage Hole (2-Way) | Funnel Strength at Bifurcation (2-Way) |